American analytical was founded to manufacture and deliver the finest GC Capillary Columns and HPLC Columns and Accessories .
AA capillaries are cross-linked and surface bonded yielding solvent rinse-able, low bleed, high performance columns. Proprietary high temperature deactivation techniques ensure the inertness needed for today’s demanding analyses.
All AA columns are individually tested to ensure proper performance. Experience has shown us that columns made from the same lot of tubing, the same deactivant and phase solutions, bonded and conditioned using the same equipment come out different. Like caring for children we carefully manufacture each column and monitor them along each step of production and testing. This benefits both you and us. You get consistent high performance columns and we get fewer failures.
Column testing should be performed both isothermally and programmed. Isothermal testing is performed first to accurately assess efficiency and inertness. Temperature programming during this phase of the testing does not yield the familiar theoretical plate counts and may hide /obscure inertness problems by artificially sharpening the peaks. Once this testing is complete the columns should be programmed up in temperature to assess the bleed levels.
AA capillary columns are pre-rinsed to ensure the completeness of the cross-linking and surface bonding. Please take the opportunity to read the Installation Manual that comes with each column. It contains vital information to ensure proper efficiency, inertness and low bleed from your new AA column.
AA-1 Capillaries Methyl silicone
Fully Cross-linked and Surface Bonded
Solvent Rinseable
Individually Tested for Inertness, Efficiency and Bleed
Temperature Limits (0.25mm
film thickness)
Minimum
-60°C
Maximum Isothermal 340°C
Maximum Programmed 350°C
AA-5 Capillary Columns
5% Phenyl methyl silicone
Fully Crosslinked and Bonded
Solvent Rinseable
Individually Tested for Inertness, Efficiency and Bleed
Temperature Limits (0.25mm
film thickness)
Minimum
-60°C
Maximum Isothermal 325°C
Maximum Programmed 340°C
Similar Phases
AT-5, BP-5, CP Sil 8CB, DB-5, Equity-5, HP-5 , MDN-5, RTx-5, SE-54, SPB-5, Ultra-2, VB-5, VF-5, XTI-5, ZB-5, 007-5
AA-1701 Capillary Columns
Fully Crosslinked and Bonded
Solvent Rinseable
Individually Tested for Inertness, Efficiency and Bleed
Temperature Limits (0.25mm
film thickness)
Minimum
-60°C
Maximum Isothermal 270°C
Maximum Programmed 280°C
Similar Phases
AT-1701, BP-10, CP Sil 19CB, DB-1701, OV-1701, RTx-1701, SPB-1701, VB-1701, ZB-1701, 007-1701
AA-Wax Capillary Columns
Fully Crosslinked and Bonded
Solvent Rinseable
Individually Tested for Inertness, Efficiency and Bleed
Temperature Limits (0.25mm
film thickness)
Minimum 40°C
Maximum Isothermal 260°C
Similar Phases
AT-Wax, BP-20, BTR-CW, CP-Wax 52CB, DB-Wax, DB-WAXetr, HP-INNOwax, Stabilwax, Supelcowax-10, VB-Wax, 007-CW
AA-FFAP Capillary Columns
Polyethylene glycol nitroterethalic acid
Fully Crosslinked and Bonded
Solvent Rinseable
Individually Tested for Inertness, Efficiency and Bleed
Temperature Limits (0.25mm
film thickness)
Minimum 40°C
Maximum Isothermal 250°C
Maximum Programmed 260°C
Similar Phases
AT-1000, BP-21, CP-Wax 58CB, DB-FFAP, HP-FFAP, Nukol, Stabilwax-DA, VB-FFAP, ZB-FFAP
The following Dimensions are available along with custom columns.
Cyclodextrin columns with a-,b-,g-CD with different percentage in different stationary phase are also available as custom columns.